RM5 Raman Microscope | Price | Raman Spectroscopy | Spectrometer
Menu

RM5 Raman Microscope

  • Truly Confocal – with variable slit and multiple position adjustable pinhole for higher image definition, better fluorescence rejection and application optimisation
  • Integrated Narrowband Raman Lasers – up to 3 computercontrolled lasers for ease of use, enhanced stability and reduced footprint
  • 5-Position Grating Turret – for unrivalled spectral resolution of 1.4 cm-1 (FWHM) and optimisation over the full spectral range 50 cm-1 – 4000 cm-1
  • Integrated Detectors – up to 2, including high efficiency CCD, EMCCD and InGaAs arrays for low noise, increased speed, high sensitivity and wide spectral range
RM5 Raman Microscope

The RM5 is a compact and fully automated Raman microscope for analytical and research purposes. The truly confocal design of the RM5 is unique to the market and offers uncompromised spectral resolution, spatial resolution, and sensitivity.

The RM5 builds on the expertise of robust and proven building blocks, combined with modern optical design considerations; and a focus on function, precision and speed. The result is a modern Raman microscope that stands alone in both specifications and ease of use.

  • Internal Standards and Auto-Calibration – to ensure the highest quality data at all times
  • 4-Position Raman Filter Turret – fully automated notch and edge filters to match the Raman range to excitation laser wavelength
  • Ramacle® Software – one powerful software package for complete system control, data acquisition, analysis and ease of upgrade
  • High Performance Microscope – compatible with all the latest accessories

For price details, further information or to find out how the RM5 Raman Microscope can assist you with your research, simply contact a member of our sales team at sales@edinst.com.

LASER SPECIFICATION  
LasersUp to 3 narrow-band lasers including: 532 nm, 638 nm, 785 nm
Other wavelengths available on request
Laser selection is fully computer-controlled
Laser Rejection FiltersUp to 3 laser rejection filters included
Filter exchange is fully computer-controlled
Laser Attenuation4 orders of magnitude, continuous
Fully computer-controlled
SPECTROGRAPH   
Spectral ResolutionFrom 1.4 cm-1 *
Spectral Range50 cm-1 - 4000 cm-1 *
SpectrographType
Focal Length
Gratings
Slits
Asymmetric Czerny-Turner
225 mm
5-position grating turret, fully computer-controlled
Continuously adjustable, fully computer-controlled
Confocal ImagingAdjustable confocal pinhole, fully computer-controlled
DETECTORS  
DetectorsStandard Detector



Optional Second Detector
High sensitivity ultra low noise CCD
1650 x 200 pixels, TE-cooled -60oC (standard) OR
2000 x 256 pixels, TE-cooled -60oC (enhanced sensitivity and spectral range)
EMCCD detector, InGaAs and others available on request
Selection of detectors, fully computer-controlled
SYSTEM  
Raman PolarisationOptionalPolarisation kit available, fully computer-controlled
Internal CalibrationWavelength calibration standard (Neon)
Raman shift standard (Silicon)
Sensitivity validation standard (Silicon)
Automated laser alignment
Microscope SystemFunctionality


Optional
Objective(s)

Sample Viewing

Sample Stage

Optional
Full upright microscope with brightfield and darkfield illuminator
Polarisation, Differential Interference Contrast (DIC) capability and fluorescence imaging
10x and 100x objective included as standard; up to 5 can be included


Trinocular eyepiece, embedded CMOS video camera, second video camera optional
XY manual stage
XYZ motorised stage (75 mm x 50 mm XY), confocal Raman mapping
Temperature-controlled sample stages available
SoftwareRamacle®
Operating System
Functionality

Optional
Comprehensive all-in-one, intuitive software package
Windows®
Data acquisition, spectrograph control, graphical display, data processing

Chemometric, spectral library packages - KnowItAllTM
Laser SafetyWithout Laser Enclosure
With Laser Enclosure
Class 3B
Class 1
DimensionsW x D x H †
Weight †
600 mm x 800 mm x 600 mm
† 63 kg
* depending on grating, laser and CCD selection
† without laser enclosure

RAMACLE® SOFTWARE

Ramacle is an exceptional software package written for complete instrument control and data handling on the RM5 system. Ramacle controls all RM5 functions with a straightforward design concept. It focuses on all modern Raman spectroscopy applications, while at the same time, providing a user-friendly interface with ‘ready to publish’ outputs.

RM5 Raman Microscope Software

The software provides control, visualisation, data acquisition, analysis and presentation of the RM5 whether it is used for generating Raman spectra or with advanced upgrades such as  Raman mapping.


Ramacle enables sample visualisation, live signal monitoring and parameter optimisation before every measurement. The instrument status and signal are displayed and constantly updated during measurements.

RM5 Raman Microscope Software

Data generated by Ramacle have a proprietary file format. This contains all measurement and instrumental properties, allowing the user to retrieve important information whenever needed and ensures data traceability. Simple input and output functions provide the required compatibility with third party data analysis or presentation packages.

KnowItAllTM Raman Identification Pro spectral library is available for material identification and advanced analysis. Data acquisition methods such as single measurements, multiple and  accumulated scans, kinetic scans and generation of maps (accessory dependent) are implemented by intuitive and in user-friendly wizards.

Ramacle Key Features

  • Selection of laser and scatter optical pathways
  • Selection of excitation wavelength, gratings and exposure time
  • Sample and laser focus visualisation
  • Programmed attenuator and shutter
  • Single, accumulated and kinetic spectral acquisitions
  • Spectral correction
  • Selection and scans of internal calibration standards and automated calibration correction
  • Data operations such as arithmetic, scaling, normalisation and baseline subtraction
  • Cosmic ray removal, cropping, smoothing
  • Automated laser alignment
  • ASCII / CSV data import / export function
  • Paste options for presentations and publications
  • Mapping features – map setup, collection and data analysis
  • Fully motorised stage – XYZ control through joystick and software
  • Polariser and analyser selection and control
  • Detectors selection
  • Laser rejection filter selection
  • External camera selection and visualisation