Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

What is a Spectrometer?

  • July 13, 2021
Edit Content

In the broadest sense a spectrometer is any instrument that is used to measure the variation of a physical characteristic over a given range; i.e. a spectrum. This could be a mass-to-charge ratio spectrum in the case of a mass spectrometer, the variation of nuclear resonant frequencies in an NMR spectrometer or the change in the absorption and emission of light with wavelength in an optical spectrometer.

What is a spectrometer? Examples of spectrometers showing: Optical spectrometer, NMR spectrometer and mass spectrometer.. Read out blog post and find out what spectrometers are used for.

Figure 1: The three most common types of spectrometers found in research labs around the world. Left: Optical spectrometer (Edinburgh Instruments FS5 spectrofluorometer). Centre: NMR spectrometer (Agilent 800 MHz NMR spectrometer). Right: Mass spectrometer (Scion Instruments GC-MS spectrometer).

The most ubiquitous type of spectrometer used for research are optical spectrometers; and when someone simply says ‘spectrometer’, without an additional qualifier, they are usually referring to an optical spectrometer and this diverse family of spectroscopic instruments is the focus of this article.

 

How does an Optical Spectrometer work?

The goal of any optical spectrometer is to measure the interaction (absorption, reflection, scattering) of electromagnetic radiation with a sample or the emission (fluorescence, phosphorescence, electroluminescence) of electromagnetic radiation from a sample. Optical spectrometers are concerned with electromagnetic radiation that falls within the optical region of the electromagnetic spectrum which is light spanning the ultraviolet, visible and infrared wavelength regions of the spectrum.

In order to gain maximum information, the interaction or emission of light should be measured as a function of wavelength and the common feature of all optical spectrometers is therefore a mechanism for wavelength selection. In low cost spectrometers or in situations where accurate wavelength selection is not important, optical filters are used to isolate the wavelength region of interest. However, for accurate wavelength selection and the generation of spectra, a dispersive element that separates light into its constituent wavelengths is required. In all modern spectrometers, this dispersive element is a diffraction grating where constructive and destructive interference is used to spatially separate polychromatic light that is incident on the grating (Figure 2).

Dispersion of light from a diffraction grating - spectrometer research example | spectrometer applications

Figure 2: Dispersion of light into its constituent wavelengths by a diffraction grating.

Diffraction gratings are a key component of a monochromator, which is a device used to select a particular wavelength of light from a polychromatic light source. In a monochromator the diffraction grating is rotated to change the wavelength that aligns with and passes through the exit slit. Excitation monochromators are found in all spectrophotometers (see following section) for selecting the desired excitation wavelength to reach the sample from a white light source (Figure 3 Excitation Monochromator) and spectra are measured by scanning the monochromator and measuring the change in signal as a function of excitation wavelength.

For detecting the light emitted by a sample there are two approaches. The first is an emission monochromator which works using the same principle as above except the light source is the emission from a sample and the monochromator selects which wavelength of light reaches the detector (Figure 3 Emission Monochromator).  The second approach is to detect the spectrum of the dispersed light ‘all at once’ using an array detector (such as a CCD camera) which is called a spectrograph (Figure 3 Spectrograph). At least one emission monochromator or spectrograph is found in all spectrofluorometers and Raman spectrometers (see following sections).

Spectrometer showing difference between a monochromator and a spectrograph

Figure 3: The basic operating principle behind monochromators and spectrographs. It should be noted that these images are highly simplified for illustration. For example the monochromators used in the Edinburgh Instruments FS5 and FLS1000 are a more complicated Czerny-Turner design which have two slits and two ellipsoidal mirrors for superior performance but the principle remains the same.

 

Types of Optical Spectrometer

Now that the key component of a spectrometer has been identified, the different types of spectrometer, their role, and basic design can be discussed.  Three of the most common optical spectrometers: spectrophotometers, spectrofluorometers and Raman spectrometers are introduced.

 

Spectrophotometer (also known as a UV-Vis Spectrometer)

The term spectrophotometer can refer to quite a variety of instruments that measure light, with the exact definition depending on the area of science or industry. In all cases the term ‘photo’ is used to indicate that the spectrometer is for the quantitative measurement of light intensity with wavelength. Within academic research (particularly chemistry and biology laboratories) the term spectrophotometer is used specifically to refer to a spectrometer which measures the absorption of light by a sample and that definition will be used here.

Simplified diagram of a single beam spectrophotometer (uv vis spectrometer)

Figure 4: Simplified diagram of a single beam spectrophotometer.

A stylised layout of a basic single beam spectrophotometer is shown in Figure 4. It comprises a white light source which is usually either a combination of a deuterium arc lamp to cover the UV range and a tungsten halogen lamp to cover the visible; or a single Xenon arc lamp to cover the entire range. This is followed by an excitation monochromator which selects the wavelength of light that reaches the sample. This light is then either transmitted through the sample (as shown in Figure 4) for transparent samples such as solutions or reflected off the surface for opaque samples. The intensity of the transmitted or reflected light is then monitored using a detector which is typically a photomultiplier tube or silicon photodiode.

In addition to stand alone spectrophotometers, the functionality of a spectrophotometer can also be incorporated as a secondary feature into other spectrometers. An example of this is the FS5 Spectrofluorometer which comes with a transmission detector as standard and has all the functionality of a single beam spectrophotometer in addition to being a spectrofluorometer.

The most common measurement undertaken in a spectrophotometer is measuring the absorption spectrum of a sample. The excitation monochromator is scanned and the change in light intensity transmitted through the sample recorded on the detector. This is then repeated with a reference sample and the absorption spectrum calculated as shown in Figure 5 for a solution of fluorescein in phosphate buffered saline.

Spectrometer measurement example: Absorption spectrum of fluorescein measured using the FS5 Spectrofluorometer.

Figure 5: Absorption spectrum of fluorescein measured using the FS5 Spectrofluorometer.

A more advanced version of a spectrophotometer is a transient absorption spectrometer, which can measure the evolution of the absorption spectrum with time and is essential for looking at temporary species generated through chemical reactions or short lived photoexcited states. The operation and design of transient absorption spectrometers are beyond the scope of this article but you can learn more in our introduction to transient absorption using the Edinburgh Instruments LP980 Transient Absorption Spectrometer.

 

Figure 6: Edinburgh Instruments LP980 Transient Absorption Spectrometer.

 

Spectrofluorometer (also known as Fluorescence/ Photoluminescence Spectrometer)

A spectrofluorometer is used to measure the fluorescence emission (or more generally, the photoluminescence) from a sample. The terms spectrofluorometer and fluorescence / photoluminescence spectrometer are interchangeable and different manufacturers call them by different names. A general convention is that spectrofluorometer refers to a compact benchtop instrument that is similar in size to a spectrophotometer, such as the FS5 Spectrofluorometer, while the term fluorescence / photoluminescence spectrometer is used for larger spectrometers with superior performance and more diverse functionality such as the FLS1000 Photoluminescence Spectrometer.

Example of a compact spectrofluorometer (FS5) and a more advanced photoluminescence spectrometer (FLS1000).

Figure 7: Example of a compact spectrofluorometer (FS5) and a more advanced photoluminescence spectrometer (FLS1000).

The layout of a typical steady state spectrofluorometer is shown in Figure 8. The excitation side of a spectrofluorometer is equivalent to the spectrophotometer: a white light source and an excitation monochromator. Xenon arc lamps are used as the light source as their high brightness is essential to measure the weak fluorescence emission. The sample is illuminated by the chosen excitation wavelength which causes it to fluoresce. The fluorescence emission is collected by the emission monochromator which is orientated at 90 degrees to the excitation monochromator and the selected wavelength reaches the detector; typically a photomultiplier tube.  For more detail on the design of spectrofluorometers read our article on fluorescence instrumentation.

Simplified diagram of a spectrofluorometer.

Figure 8: Simplified diagram of a spectrofluorometer.

The two most common spectral measurements undertaken in a spectrofluorometer are excitation and emission spectra.  To measure an excitation spectrum the emission monochromator is set at a wavelength of strong fluorescence emission, the excitation monochromator is scanned across the wavelength region of interest and the change in fluorescence intensity monitored on the detector (Figure 9 blue curve) which reveals the absorption features of sample. Emission spectra are the inverse of this; the wavelength of the excitation monochromator is set where there is strong absorption by the sample, the emission monochromator is swept across the wavelength region of interest and the change in fluorescence detected (Figure 9 red curve) revealing the fluorescence features of the sample.

Spectrometer application diagram: Fluorescence excitation (blue) and emission (red) spectra of anthracene measured using the FS5 Spectrofluorometer.

Figure 9: Fluorescence excitation (blue) and emission (red) spectra of anthracene measured using the FS5 Spectrofluorometer.

 

Raman Spectrometer

Raman spectrometers are used to measure the Raman scattering of light from a sample. The design of a typical Raman spectrometer is shown in Figure 10 and is similar to a spectrofluorometer but with a few key differences. The white light source and excitation monochromator found in spectrofluorometers are replaced with a laser. The reason for this is twofold. The first is that ‘Raman’ is a scattering effect and the light is therefore not absorbed by the sample. This means that a broadband tuneable light source for matching to the absorption features is not required. The second reason is that the Raman effect is much weaker than fluorescence (ratio of Rayleigh scattered light to Raman scattered light is ~106) and sources with a high photon flux are therefore essential to maximise the signal.

Raman spectrometer diagram

Figure 10: Simplified diagram of a Raman spectrometer.

The laser light is scattered off the sample and passed through a filter to remove the much more intense Rayleigh scattered component. The remaining Raman scattered light is then passed into a spectrograph and captured using a CCD detector to give a Raman spectrum like that shown in Figure 11 of paracetamol.

paracetamol raman spectrum with results recorded on a spectrometer by Edinburgh Instruments

Figure 11: Raman spectrum of paracetamol.

 

Keep in Touch

If you have enjoyed reading this blog post about our spectroscopic instruments, and want to be the first to see all the latest news, applications and product information, then sign-up to our infrequent newsletter via the red sign-up button below and join us on social media.

RELATED PRODUCTS

RM5

Raman Microscope

VIEW

DS5

Dual Beam UV-Vis Spectrophotometer

VIEW

LP980

Transient Absorption Spectrometer

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous What is Upconversion? Next Raman Spectroscopy: Measurement Examples

RESOURCES

Tags:
  • Spectral School
  • FLS1000
  • FS5
  • IR5
  • LP980
  • RM5
  • RMS1000
  • FTIR
  • Photoluminescence
  • Raman
  • Transient Absorption
  • UV-Vis
Suggested Reading:

What is the Difference between Luminescence, Photoluminescence, Fluorescence, and Phosphorescence?

View more »

What is Transient Absorption Spectroscopy?

View more »

What is Raman Spectroscopy?

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}