Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers:

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes:

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption:

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers:

    • IR5 FTIR Spectrometer

    Lasers and LEDs:

    • Pulsed Lasers
    • Gas Lasers

    Options:

    • Upgrades
    • Customisation
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
  • About Edinburgh Instruments
  • Products
  • Techniques
  • Applications Old
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

What is Transient Absorption Spectroscopy?

  • July 8, 2021

KEY POINTS

  • Transient absorption spectroscopy is a pump-probe technique that measures changes in absorption after photoexcitation, used to track excited-state dynamics and short-lived transient species.
  • The technique reveals key photophysical and photochemical processes, including singlet and triplet excited states, electron and energy transfer mechanisms, and photoproduct formation.
  • Transient absorption is widely used to study photochemical processes, from photosynthesis to solar energy conversion, across ultrafast to longer timescales.

Transient absorption spectroscopy, also known as flash photolysis, is a pump-probe spectroscopic technique utilised to measure the photogenerated excited state absorption energies and associated lifetimes of molecules, materials, and devices.

The pump-probe technique can be described by a sample being photo-excited by a light source (pump pulse), whereby a second light source (probe pulse) is measured for changes in absorption as a function of wavelength and time. The technique focuses on measuring excited singlet and triplet states, electron and energy transfer mechanisms, and photo-product reactions, to name a few.

It has broad implications to photochemical science, from understanding the light-harvesting mechanism of photosystem-II (PS-II) in plants, to signalling of the human retina, to optimising solar cells and light driven photo-catalysis.

 

History of Transient Absorption Spectroscopy

The technique was first published in 1950 by George Porter and Ronald G. W. Norrish, who discovered that high-intensity flash tubes used in World War II for aerial photography could be utilised to initiate a light-activated reaction.1 This seminal work, along with additional studies, earned them a share of the 1967 Nobel Prize in Chemistry, notably “for their studies of extremely fast chemical reactions, effected by disturbing the equilibrium by means of very short pulses of energy”.

Before then, reaction kinetics had been limited to timescales of hundreds of milliseconds using the stopped flow technique, but transient absorption enabled measurements in the microsecond range. Their pioneering work opened up a new field as it allowed the study of fast photochemical reactions.

Transient absorption has continued to develop since its discovery with increasing time resolution, reaching the femtosecond scale in the 1990s thanks to advances by Nobel prize winner Ahmed Zewail.

 

Pump Probe | What is Transient Absorptioin?

Figure 1. Manfred Eigen, Ronald G.W. Norrish, and George Porter, winners of the 1967 Nobel Prize in Chemistry.2

 

Transient Absorption Timescales and Flash Photolysis

Nanosecond transient absorption (nsTA) is commonly referred to by its original name, flash photolysis, although it does not always involve photodissociation. There are two timescales that present different instrumentation needs and challenges: nsTA, and ultra-fast, femtosecond transient absorption (fsTA). Both are also referred to as pump-probe spectroscopy and the data reported in both show photogenerated transient kinetics and spectra with varying timescales. fsTA is often used to probe singlet excited states and fast processes such as photoisomerisation, solvent relaxation, and charge injection. In contrast, nsTA is employed for studying triplet states, energy transfer, electron transfer radicals, back electron transfer, and triplet-triplet annihilation in everything from biomolecular reactions to solar cell efficiency.

Edinburgh Instruments specialises in nsTA measurements on the LP980 Transient Absorption Spectrometer, with measurable lifetimes from approximately 5 ns to seconds.

Excited states are generated by an excitation pulse of light (pump pulse), and the spectra and lifetimes of the transient species are measured as a change in a baseline of light (probe pulse) at the desired wavelength(s). This method typically employs a high energy Nd:YAG laser as the pump source, and a white light halogen bulb and monochromator or an individual wavelength LED as the probe source. Lifetimes are typically monitored using a photomultiplier tube’s (PMT) response as recorded by an oscilloscope. Transient absorption spectra can either be generated from the PMT responses at individual wavelengths, or more quickly by utilising an intensified-CCD (ICCD) camera to acquire time-gated transient spectra.

 

Understanding Transient Absorption Spectra

Figure 2 shows the simple case of a sample with a ground state (G) and excited states (A and B), carried out on a nanosecond transient absorption spectrometer featuring a white light probe source and a single-wavelength pump laser. After the sample, the probe beam passes through a monochromator, allowing the ground and excited absorbance changes of the sample to be measured at a particular wavelength.

Schematic of a transient absorption spectroscopy measurement, showing the ground and excited absorbance changes of the sample

Figure 2. Schematic of a transient absorption experiment.

 

In the absence of photoexcitation, most species are in the ground state (G). At t < 0, before the pump laser excites the sample and the probe beam is incident on the sample, the detector observes the intensity of the ground state (G) absorption resulting in the spectrum OD0.

The pump pulse reaches the sample at t = 0 and creates a high, non-equilibrium population in the excited state A.

At t > 0, the probe detects absorption from A → B as well as G → A. Due to excited state absorption, a new component appears in the spectrum at ODt, as well as a reduction in the ground state absorption. The decrease in G → A occurs because the pump pulse has depleted the ground state; this is known as ground state bleach.

The transient absorption spectrum ΔODt measures the difference between ODt and OD0 and represents the change in absorption effected by the pump laser pulse. As the sample relaxes back into the G state, its ΔOD spectrum changes with time, eventually reaching zero.

 

References

  1. G. Porter, Proc. R. Soc. A, 1950, 200, 284–300.
  2. NobelPrize.org, The Nobel Prize in Chemistry 1967, https://www.nobelprize.org/prizes/chemistry/1967/summary/, (accessed July 2021).
Read More Read Less

RELATED PRODUCTS

LP980

Transient Absorption Spectrometer

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous What is Resonance Raman Spectroscopy? Next How to Choose Your Lasers for Raman Spectroscopy

RESOURCES

Tags:
  • Spectral School
  • LP980
  • Transient Absorption
Featured Product:

LP980 Transient Absorption Spectrometer

View more »
Suggested Reading:

Temperature Dependent Triplet States of Benzophenone; Spectral and Lifetime Measurements Utilising Transient Absorption Spectroscopy

View more »

Kinetics of Photocatalysis Reactions Studied by Transient Absorption Spectroscopy

View more »

An Introduction to Flash Photolysis using the LP980 Spectrometer

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Edinburgh Instruments
  • Techniques
  • Applications
  • Knowledgebase
  • About Edinburgh Instruments
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Distribution & Agents
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • Coordinated Vulnerability Disclosure Policy
  • News
  • Events
  • Blog
  • Careers
  • Distribution & Agents
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • Coordinated Vulnerability Disclosure Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2026 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}