Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  1. Home
  2. Blog Post
  3. Graphene Analysis: How to Configure Your Raman Microscope

BLOG

Graphene Analysis: How to Configure Your Raman Microscope

  • June 12, 2024
Edit Content

In our ongoing Year of Graphene series, we’ve showcased why Raman microscopy is ideal for analysing graphene and other 2D materials. But what exactly is a Raman microscope, and what factors should be considered to optimise it for graphene analysis? 

The Raman Microscope

Let’s break down the basics of a confocal Raman microscope. The starting point is always the laser (shown in red), the wavelength of which profoundly influences the resulting spectrum, impacting both signal intensity and spectral resolution. This laser light is directed onto the sample via a microscope (green), equipped with an objective lens. The choice of objective lens determines the spatial resolution, with higher magnification allowing finer details to be resolved. 

When the laser interacts with the graphene sample, Raman scattering occurs. The objective collects this scattered light, which is then directed to a spectrograph for detection (blue). The spectrograph separates the light into its constituent wavelengths, and it is then detected using a sensitive camera called a charged-coupled device (CCD) to give the Raman spectrum of the graphene. 

Figure 1: Layout of a Raman Microscope  

Optimising for Graphene

Raman microscopes are used in every area of science and technology. You’ll find them in biology, chemistry, and physics academic labs; and in industry for both R&D and quality control. To cater to this broad spectrum of applications, the components of a Raman microscope can be tailored to meet specific requirements. Consequently, when analysing graphene (and related materials), what factors should be taken into account? 

The primary consideration in analysing graphene is the choice of laser wavelength. There are 3 main bands of interest in the Raman spectra of graphene, the G-band, the D-band, and the 2D-band. 532 nm excitation is commonly used for graphene characterisation due to its strong resonance enhancement of the G-band and 2D-band. These bands are indicative of the number of layers of graphene present and the quality of the sample. Briefly, resonance Raman spectroscopy uses a laser with a wavelength that matches an electronic transition of the molecule, enhancing the Raman scattering signal and providing detailed information about molecular structure and dynamics in a sample. 

Figure 2: Raman spectrum of graphene 

Most Raman microscopes can accommodate more than one laser, and 633 nm is a popular alternative laser wavelength. While 633 nm excitation is less commonly used for graphene analysis compared to 532 nm, it can still provide valuable insights, especially for samples where the 532 nm laser may induce unwanted effects such as photodegradation. Due to the resonance properties of the main bands of graphene, it is important to always use the same laser wavelength when investigating samples to allow for comparisons to be made. 

Another method to prevent photodegradation is to control the laser power interacting with the sample. Therefore, Raman microscopes typically feature laser attenuation, which the user can adjust to ensure that the selected laser does not damage the sample. 

Achieving high spatial resolution is essential when examining graphene samples, such as flakes. This can be accomplished by using high-magnification objectives. In Raman microscopes, objectives can be easily exchanged, allowing users to capture low-resolution Raman images to identify areas of interest and then switch to higher-resolution objectives to achieve precise spatial resolution. 

Graphene peaks are relatively close together in the spectrum, and a high spectral resolution is required for accurate peak fitting and quantitative analysis of properties such as layer thickness and defect density. This is where the spectrograph’s grating comes into play. Configuring the Raman microscope with a high-resolution grating means these peaks can be accurately resolved, and an 1800 gr/mm or 2400 gr/mm grating is recommended.  

The final decision is the CCD detector. In Raman microscopy, two types of CCDs are used: front-illuminated and back-illuminated. A back-illuminated CCD is preferred for analysing graphene because it allows more efficient detection of Raman scattered light. In a back-illuminated CCD, the light enters the sensor from the backside, directly reaching the photosensitive silicon layer without obstruction from metal wiring or other layers. This improves signal-to-noise ratio and enhances sensitivity, particularly for thin or transparent samples like graphene. 

Want to see it in Action?

In this demonstration, our Raman Applications Scientist, Dr Matthew Berry, demonstrates how the different components of the RM5 Raman microscope discussed above influence the measured spectrum. Using the Ramacle® RM5 software he shows how to optimise the microscope parameters to acquire the optimal spectrum of a sample. 

 

RELATED PRODUCTS

RMS1000

Multimodal Confocal Microscope

VIEW

RM5

Raman Microscope

VIEW

RESOURCES

Tags:
  • 20 Years of Graphene
  • 2D Materials
  • RM5
  • RMS1000
  • Raman
Share:
PrevPrevious
NextNext

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}