Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

The Rayleigh Criterion for Microscope Resolution

  • July 8, 2021

KEY POINTS

  • The Rayleigh criterion determines the minimum separation for distinguishing two objects in microscopy, based on the overlap of Airy patterns.
  • The criterion is not a fundamental law but a convenient definition of resolution.
  • This article also discusses other resolution limits such as the Sparrow limit, Abbe limit and FWHM.
Edit Content

The lateral (X-Y) resolution of fluorescence and Raman microscopes is frequently calculated using the famous Rayleigh Criterion for resolution, 0.61λ/NA, but where does this resolution limit arise from and how does it relate to the other resolution limits encountered in microscopy? 

 

The Point Spread Function & Airy Pattern

When a point emitter (such as a quantum dot) is imaged by a microscope, its image is blurred due to diffraction. The diffraction pattern of a point emitter in the image plane of a microscope is described by the 2D point spread function (PSF). For a perfect imaging system with no aberrations, this pattern is also known as the Airy pattern and is shown in Figure 1. It consists of a bright central circle, the Airy disc, which contains 84% of the total light intensity, with the remaining 16% distributed across a series of progressively less intense concentric rings. The size of the Airy disc is given by:

Where λ is the wavelength of the emitted or scattered light and NA is the numerical aperture of the microscope’s objective lens. NA is a measure of the objective’s ability to capture light and is the product of the sine of the half-angle of the objective’s acceptance cone, α, and the refractive index, n, of the medium between the sample and objective lens:

point spread function airy disc

Figure 1: 2D-Point Spread Function / Airy Pattern of a point emitter.

 

What is Resolution?

Resolution can be defined as the minimum separation between two objects that results in a certain level of contrast between them. When two objects are brought together their PSFs combine additively and the total PSF of both objects is what is imaged by the microscope. When the objects are sufficiently far apart there is a dip in the intensity of the total PSF between the objects and they can be distinguished as separate entities and said to be resolved. The various microscopy lateral resolution limits, of which the Rayleigh criterion is but one, are essentially just different definitions of what constitutes a sufficient level of contrast between the objects for them to be resolved.

overlapping point spread fucntions

Figure 2: Overlap of PSFs and resolution of two point emitters at different radial distances.

 

Rayleigh Criterion

The Rayleigh criterion is named after English physicist John William Strutt, 3rd Baron Rayleigh (1842-1919) who investigated the image formation of telescopes and microscopes in the late 19th century. Rayleigh defined the resolution limit as the separation where the central maximum of the Airy pattern of one point emitter is directly overlapping with the first minimum of the Airy pattern of the other.1,2 In other words, the minimum resolvable separation between the points is the radius of the Airy disc which is given by:

Rayleigh criterion

Figure 3: Two points separated by the Rayleigh resolution limit.

Rayleigh chose his criterion based on the human visual system and to provide sufficient contrast  for an observer to distinguish two separate objects in the image. The Rayleigh criterion is therefore not a fundamental physical law and instead a somewhat arbitrarily defined value. This was clearly stated by Rayleigh himself in 1879:2

This rule is convenient on account of its simplicity; and it is sufficiently accurate in view of the necessary uncertainty as to what exactly is meant by resolution.

This does not make it any less useful and the Rayleigh criterion has become one of the most ubiquitous definitions of microscope resolution.

 

Sparrow Limit

The Sparrow limit is a less commonly encountered resolution limit proposed by the American physicist Carrol Mason Sparrow (1880 – 1941) in 1916.3 Sparrow’s limit is defined as the separation between two point emitters when the total PSF has no dip in intensity at the midpoint and there is instead an intensity plateau between the points. The Sparrow limit is, therefore, smaller than that defined by Rayleigh and is given by:

sparrow limit

Figure 4: Two points separated by the Sparrow resolution limit.

 

Abbe Limit

Ernst Abbe (1840 – 1905), was a German physicist who made pioneering contributions to the design and theory of optical microscopy. He was a research director at Zeiss Optical Works (now ZEISS) and introduced the concept of numerical aperture to describe optical systems. In 1873 Abbe published his seminal paper on image formation in microscopes, “Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung” (Contributions to the Theory of the Microscope and the Nature of Microscopic Vision).4 The original paper is in German but a modern English translation can be found in Barry R. Masters book on super-resolution microscopy.5 Abbe’s 1873 paper is unusual in that it contained not a single equation. In it, Abbe profoundly stated that microscope resolution is determined by the wavelength of light the numerical aperture of the objective, and this was later formulated into the equation now known as the Abbe limit for resolution:

abbe limit

Figure 5: Two points separated by the Abbe resolution limit.

 

FWHM

A more practical definition of microscope resolution is to use the FWHM of the point spread function (see Figure 1) which has a theoretical minimum value of:

The advantage of using the FWHM is that it can be easily measured in the lab by imaging a pseudo point emitter (such as a sub-resolution fluorescent bead) and therefore be used as a comparison metric for real microscope systems – in contrast to the other limits which are theoretical ideals.

fwhm resolution

Figure 6: Two points separated by the FWHM.

 

References

1. L. Rayleigh, On the theory of optical images, with special reference to the microscope. London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, 42, Part XV, 167–195 (1896)

2. L. Rayleigh, Investigations in optics, with special reference to the spectroscope. London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, 8, Part XXXI, 261–274 (1879)

3. C. M. Sparrow. On spectroscopic resolving power. Astrophysical Journal, 44, 76–86 (1916)

4. E. Abbe, Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung. Archiv für mikroskopische Anatomie, IX, 413–468 (1873)

5. R. Masters, Superresolution Optical Microscopy, Springer Series in Optical Sciences (2020)

 

RELATED PRODUCTS

MicroPL

Spectromicroscopy Upgrade

VIEW

RMS1000

Multimodal Confocal Microscope

VIEW

RM5

Raman Microscope

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous What is Raman Spectroscopy? Next What is Surfaced Enhanced Raman Scattering (SERS)?

RESOURCES

Rayleigh Criterion
Tags:
  • Spectral School
  • RM5
  • RMS1000
  • Raman
Related Posts:
EI-FS5 v2+Microscope

MicroPL

View more »

RMS1000 Raman Microscope

View more »

RM5 Raman Microscope

View more »
Suggested Reading:

What is Confocal Raman Microscopy?

View more »

Role of the Pinhole in a Confocal Microscope

View more »
Laser Spot Size

Laser Spot Size in a Microscope

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}