Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

Measuring Photoluminescent Properties of Gallium Nitride

  • February 12, 2025

KEY POINTS

  • Gallium nitride (GaN) is a promising semiconductor material which significantly outperforms silicon-based devices, however, high quality of GaN is crucial for optimal performance.
  • Photoluminescence (PL) spectroscopy provides a non-destructive method to assess GaN quality by analysing its emission properties and identifying defects.
  • Measuring steady-state and time-resolved PL in GaN distinguishes intrinsic properties from defect-related emissions, providing valuable insights into material quality.
Edit Content

Gallium nitride (GaN) has emerged as a leading material in the semiconductor industry, offering significant advantages over traditional silicon-based technologies. GaN is a binary III/V semiconductor with a direct bandgap of around 3.4 eV, which is over three times that of silicon (1.1 eV).1,2 This wide bandgap allows GaN to withstand high electric fields, leading to smaller and more efficient power electronics used for processing high voltages and currents.

The large bandgap of GaN leads to electroluminescence emission of near-UV to blue light, making GaN extremely useful for UV and blue light-emitting diodes (LEDs) and lasers.3 Other useful properties of GaN include its durability, high conductivity and high heat capacity. These make GaN an ideal candidate for use in transistors used in high-voltage and high-temperature applications such as wireless communication infrastructure and aerospace technologies.

It is important to ensure GaN materials are high quality with minimal mechanical and electrical heterogeneity caused by strain and crystal defects. Photoluminescence (PL) offers a sensitive, non-destructive technique for assessing the quality of GaN materials. When defects are present in the material, defect-induced energy levels with lower bandgaps are formed causing the emission of radiation of different wavelengths.4 Common defects in GaN produce luminescence in the yellow range.

Time-resolved PL measurements provide additional insight into the quality of GaN materials. GaN exhibits very fast PL lifetimes in the picosecond to nanosecond range. In contrast, defects typically exhibit longer lifetimes in the microsecond to second range.4

This Application Note demonstrates the use of an Edinburgh Instruments FLS1000 Photoluminescence Spectrometer coupled to an external picosecond pulsed UV laser to perform both steady-state and time-resolved PL measurements of GaN.

 

Materials and Methods

Measurements were performed using an FLS1000 equipped with an externally coupled 266 nm picosecond pulsed laser (PS-D-266_Air_A_10mW, CNI Laser) and a high-speed hybrid-PMT detector (HS-HPD) (Figure 1).

The analysed sample was undoped n-type GaN on a sapphire substrate manufactured using the halide vapour phase epitaxy (HVPE) growth method. The sample was placed in a front-face sample holder, and the setup included a 325 nm longpass filter placed before the emission monochromator to eliminate laser scattering as the sample was reflective.

Time-resolved PL measurements of GaN were collected using time-correlated single photon counting (TCSPC) with a laser repetition rate of 500 kHz. The GaN defects were identified using multichannel scaling (MCS) with a microsecond xenon flashlamp at a 100 Hz repetition rate.

FLS1000 spectrometer

Figure 1. FLS1000 spectrometer with an externally coupled 266 nm laser, front-facing sample holder, and hybrid PMT detector used for PL measurements of GaN.

 

Steady State PL of GaN

PL spectroscopy is a useful approach for determining energy gaps, particularly in wide bandgap semiconductors such as GaN. The emission spectrum of GaN, shown in Figure 2, exhibits a peak at 365 nm corresponding to a bandgap energy of 3.4 eV. This peak originates from the band-edge emission of GaN, resulting from the direct band-to-band recombination between electrons in the conduction band and holes in the valence band.

In addition, a broader luminescence band at around 550 nm (2.25 eV) was observed corresponding to defect-related emission in the GaN. This defect luminescence in the material is often attributed to gallium vacancy-related defects.

Emission spectrum of Gallium Nitride

Figure 2. Emission spectrum of GaN. Measurement parameters: λex = 266 nm, Δλem = 1 nm, step = 0.5 nm, dwell time = 1 s.

 

PL Lifetime of GaN

PL Lifetimes were collected at 370 nm and 550 nm emission to evaluate GaN and defects, respectively. The PL lifetime of the GaN band-edge emission at 370 nm was measured using TCSPC. The instrument response function (IRF) was measured at the laser wavelength (266 nm). The fluorescent decay, IRF and calculated lifetime are shown in Figure 3.

Fluorescence decay and calculated photoluminescence lifetime of gallium nitride

Figure 3. Fluorescence decay and calculated PL lifetime of GaN at 370 nm emission. Measurement parameters: λex = 266 nm, Δλem = 1 nm, repetition rate = 500 kHz.

The decay was fitted as a reconvolution of the IRF and the exponential decay of the sample. The photoluminescence decay was fitted with a three-component exponential giving relaxation times of 0.26, 0.77 and 5.78 ns. This yielded an intensity average lifetime of 1.11 ns.

The PL lifetime of the defect emission at 550 nm was also measured using MCS single photon counting and a microsecond xenon flashlamp excitation source (Figure 4).

Fluorescence decay and calculated PL lifetime of GaN at 550 nm emission.

Figure 4. Fluorescence decay and calculated PL lifetime of GaN at 550 nm emission. Measurement parameters: λex = 365 nm, Δλex = 1 nm, Δλem = 3 nm, repetition rate = 100 Hz.

The decay was fitted using a three-component exponential giving relaxation times of 141.2, 915.2 and 2906.8 µs, resulting in an intensity average lifetime of 2.22 ms. The longer lifetime in the range of microsecond to second was characteristic of defects in GaN, demonstrating that this technique was effective for assessing the quality of GaN materials.

 

Conclusion

The FLS1000 spectrometer coupled with an external UV laser allowed measurement of steady state and time-resolved PL of GaN. The steady state PL spectrum showed emission bands typical of crystalline GaN and GaN with structural defects. Time-resolved PL measurements of these emission bands confirmed this. The combination of steady state and time-resolved PL analysis is an effective tool for characterising the quality of GaN.

 

References

  1. F. David et al., Critical evaluation of the status of the areas for future research regarding the wide band gap semiconductors diamond, gallium nitride, and silicon carbide, MSEB, 1988, 1, 77-104.
  2. Santana et al., Photoluminescence Study of Gallium Nitride Thin Films Obtained by Infrared Close Space Vapor Transport, Materials (Basel), 2013, 6, 1050-1060.
  3. S. Nakamura et. al., High-power GaN P-N junction blue-light-emitting diodes, Jpn. J. Appl. Phys., 1991, 30, L1998
  4. M. A. Reshchikov et al., Luminescence properties of defects in GaN, J. Appl. Phys., 2005, 97, 061301

RELATED PRODUCTS

FLS1000

Photoluminescence Spectrometer

VIEW

FS5

Spectrofluorometer

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous Raman Microscopy for Flexible Zinc-Air Battery Design Next Raman Spectroscopy of Silicon Carbide Semiconductor Wafers

RESOURCES

Tags:
  • Application Notes
  • LEDs and Lighting
  • Semiconductors
  • TCSPC
  • FLS1000
  • FS5
  • Photoluminescence
Application Note
Download PDF
Featured Product:

FLS1000 Photoluminescence Spectrometer

View more »
Suggested Reading:

Raman and Photoluminescence Characterisation of GaN

View more »

What is Multichannel Scaling (MCS)?

View more »

TCSPC – What is Time-Correlated Single Photon Counting?

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}