Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

What is Förster Resonance Energy Transfer (FRET)?

  • May 14, 2024
Edit Content

Förster resonance energy transfer (FRET) is a photophysical mechanism in which energy is transferred from an excited molecule (the donor) to another molecule (the acceptor) via a dipole-dipole resonance interaction.  

When a donor molecule is photoexcited (D*), an oscillating dipole is generated and if the acceptor molecule (A) is in close proximity to the donor (typically between 1 and 10 nm), the dipole of the donor induces a dipole in the acceptor molecule, leading to the deactivation of the donor and the excitation of the acceptor (Figure 1). 

Foster resonance energy transfer mechanism

Figure 1. FRET mechanism between a donor (D) and acceptor (A). Excited state molecules are represented by *. 

 

What are the Requirements for Förster resonance energy transfer? 

There are two key requirements for FRET to occur: 

  • A spectral overlap between the donor emission and the acceptor absorption, which is quantified as the spectral overlap integral.  
  • The donor and acceptor molecules are in close proximity, typically 1- 10 nm. 

spectral overlap for FRET fluorescence

Figure 2. Requirements for FRET. 

 

How to Calculate the FRET Transfer Efficiency 

The efficiency of energy transfer, η, is given by Eq. 1: 

 

 

 

where r is the centre-to-centre distance between the donor and the acceptor and R0 is the Förster radius which is the distance at which the transfer efficiency is 50%. FRET is a dipole-dipole mechanism and the efficiency therefore drops off as 1 / r6. FRET will therefore only take place when the donor and acceptor are in close proximity, typically between 1 nm – 10 nm. 

The Förster radius R0 is given by Eq. 2: 

 

 

where k2 is the orientation factor and n is the refractive index of the medium containing the donor and acceptor. ΦD is the photoluminescence quantum yield of the donor in the absence of acceptor.   J is the spectral overlap integral which quantifies the spectral overlap between the donor emission and acceptor absorption shown in Figure 2. 

 

Comparison of FRET and Dexter Energy Transfer 

The other famous energy transfer is Dexter. An important difference between the two mechanisms is their dependence on distance (Figure 3). FRET is a dipole-dipole interaction mechanism which falls off as 1/r6 while Dexter is an electron exchange mechanism that requires orbital wavefunction orbital and the transfer efficiency therefore falls off much more rapidly (exponentially). FRET therefore occurs over longer distances than Dexter. The other important difference is that FRET is a singlet-only process while Dexter can proceed via both singlet and triplet excited states. 

 FRET energy transfer distance dependence

Figure 3: FRET and Dexter energy transfer dependence on distance. R0 is the Förster radius. 

 

PrevPrevious
NextNext
Previous What is a Fluorescence Spectrometer? Next What is Dexter Energy Transfer?

RESOURCES

Tags:
  • Spectral School
  • FLS1000
  • FS5
  • Photoluminescence
Download PDF
Featured Product:
EI-FS5 v2+Microscope

MicroPL

View more »

FLS1000 Photoluminescence Spectrometer

View more »

FS5 Spectrofluorometer

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}