Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

Sb to Mn Energy Transfer Revealed using Time-Resolved Emission Spectroscopy

  • March 3, 2022
Edit Content

Zero-dimensional (0D) metal halide hybrids are an emerging class of semiconducting materials for optoelectronic applications including light-emitting diodes, lasers and photovoltaics. Heterometallic (comprising of more than one type of metal centre) metal halide hybrids, in particular, hold great promise due to the potential for synergistic photo-physical properties depending on the choice of the constituent metal centres.1 In this application note time-resolved emission spectroscopy (TRES) with the FLS1000 Photoluminescence Spectrometer is used to identify the emission pathways in the 0D metal halide hybrid, Tris SbMnCl.

 

Methods & Materials

Tris SbMnCl was prepared by researchers at the Indian Institute of Science Education and Research (IISER) Tirupati and full synthesis details can be found in the accompanying publication.1 The photoluminescence properties were characterised using an Edinburgh Instruments FLS1000 Photoluminescence spectrometer equipped with a VPLED310 Variable Pulse Width Light Emitting Diode and Multichannel Scaling (MCS) Lifetime Electronics.

FLS1000 Photoluminescence Spectrometer

Figure 1: FLS1000 Photoluminescence Spectrometer.

 

Steady State Emission Spectrum of Tris SbMnCl

The Tris SbMnCl was excited with the VPLED310 source in CW mode. The VPL/VPLED series are pulsed diode lasers and LEDs with a user-settable pulse width (50 ns to 1 ms) in addition to a CW mode that provides continuous excitation for spectral measurements. The emission spectrum of Tris SbMnCl, when excited at 310 nm, is shown in Figure 2, revealing a bright emission centred at 635 nm. To identify which metal centres are contributing to this emission, time-resolved emission spectroscopy (TRES) can be utilised

emission spectrum of metal halide hybrid | Time-Resolved Emission Spectroscopy

Figure 2: Emission spectrum of Tris SbMnCl.

 

Time-Resolved Emission Spectra (TRES) of Tris SbMnCl

In TRES, a pulsed excitation source excites the sample, and the resulting photoluminescence decay is recorded sequentially as a function of emission wavelength to create a 3D dataset that contains the spectral and time evolution of the photoluminescence. The Fluoracle® operating software of the FLS1000 enables automated TRES spectra to be acquired using either TCSPC or MCS mode for measuring short and long lifetimes respectively.

To acquire the TRES of Tris SbMnCl the VPLED310 was set to a pulse width of 100 ns and a repetition rate of 10 Hz. The photoluminescence decays were acquired using MCS mode over a wavelength range of 400 to 900 nm in 4 nm steps. Two TRES profiles of Tris SbMnCl were measured, the first focusing on the 0-20 µs time range with a time-resolution of 50 ns (Figure 3a & 3b); and a second over a time range of 50 ms with a lower time-resolution of 10 µs (Figure 3c & d) to capture the long timescale behaviour.

time-resolved emission spectra of Sb & Mn emission

Figure 3: TRES of Tris SbMnCl acquired over (a) a 20 µs time range and (b) a 50 ms time range. Extracted decays at λem = 650 nm are shown in panels (b) & (d).

Looking first at the short timescale behaviour in Figures 3a & 3b, upon excitation there is a prompt emission channel that decays within the first 20 ns followed by an intermediate channel that decays over the next ~7 µs (τ= 904 ns). Both processes emit broadly over the measured wavelength range. This is followed by a slower emission channel which appears static in the 20 µs time range of Figures 3a & 3b but can be clearly seen within the 50 ms time range of Figures 3c & 3d as a decay lasting ~40 ms (τ= 6.01 ms). The ms channel is notably narrower than the ns & µs channels, emitting over a 550 nm to 800 nm wavelength range.

The spectra associated with each emission channel can be obtained by integrating the corresponding time range of the TRES profile in Fluoracle, and the normalised spectra of the three channels are shown in Figure 4a. The ns and µs channel spectra are broad spanning 400 nm to 900 nm with the ns channel blue-shifted with respect to the µs. This broad emission on a ns and µs timescale is characteristic of Sb emission in 0D chloride hybrids.2 When excited with high energy photons (~ 300 nm) both the singlet and triplet self-trapped exciton (STE) manifolds in 0D Sb chlorides are populated. The radiative transition of the singlet and triplet STEs leads to a higher energy fluorescence emission on a ns and a lower energy phosphorescence emission on a µs timescale respectively which agrees with Figure 4a, and the ns & µs emission channels can therefore be assigned to emissive Sb centres in Tris SbMnCl. The ms timescale emission centred at 635 nm is also observed in the parent compound Tris MnCl (no Sb doping) and is distinctive of Mn2+centre emission which has a long lifetime due to a spin forbidden radiative transition.1 The ms emission channel can therefore be assigned to emissive Mn centres in Tris SbMnCl.

Mn and Sb emission spectra | Time-Resolved Emission Spectroscopy

Figure 4: Emission spectra of the ns, µs & ms channels of Tris SbMnCl with (a) normalised intensities and (b) relative intensities.

The relative intensity of the three emission channels are compared in Figure 4b. The Mn centre emission is clearly stronger than the ns and µs channels of the Sb centres, with the Mn centre emission accounting for >95% of the total photoluminescence. Absorption and photoluminescence excitation studies have shown that at the 310 nm excitation wavelength used here, Sb centres are the dominant absorbing species and Tris MnCl is much less emissive than Tris SbMnCl when excited at this wavelength.1 This information in combination with calculation of >95% photoluminescence intensity from Mn centres obtained from the TRES reveals that the Sb centres are acting as antennae, harvesting the excitation energy and then transferring this energy to the emissive Mn centres that act as acceptors. Full details on the supporting measurements for this energy transfer mechanism can be found in the accompanying publication.1

 

Conclusion

Time-resolved emission spectroscopy (TRES) is a powerful technique for characterising the emission in materials with multiple emission channels. The FLS1000 can undertake automated TRES measurements in both TCSPC and MCS mode, covering the full range of lifetimes from picoseconds to seconds.  A wide range of excitation sources are available to suit sample requirements including flashlamps, pulsed diode lasers, pulsed light-emitting diodes, supercontinuum lasers all of which can be used for TRES.

 

References

  1. Biswas et al. Synergistic electronic coupling/cross-talk between the isolated metal halide units of zero dimensional heterometallic (Sb, Mn) halide hybrid with enhanced emission Mater. Chem. C, 2022, 10, 360–370
  2. Li et al. Dual-Band Luminescent Lead-Free Antimony Chloride Halides with Near-Unity Photoluminescence Quantum Efficiency Mater. 2019, 31, 22, 9363–9371

RELATED PRODUCTS

FLS1000

Photoluminescence Spectrometer

VIEW

FS5

Spectrofluorometer

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous Fluorescence Microscopy with the FS5 Spectrofluorometer Next Relative Quantum Yield of 2-Aminopyridine

RESOURCES

Tags:
  • Application Notes
  • Photophysics
  • FLS1000
  • FS5
  • Photoluminescence
Download PDF
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}