Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  1. Home
  2. Blog Post
  3. Fluorescence Spectroscopy: Measuring Fluorescence from a Sample

BLOG

Fluorescence Spectroscopy: Measuring Fluorescence from a Sample

  • August 17, 2018
Edit Content

Fluorescence spectroscopy is a widespread analytical technique, often used for the analysis of a sample by defining the concentration of a chemical substance in a sample. However, measuring fluorescence from unknown samples can often be challenging even for experienced users. Below is a procedure for spectral measurements to help newcomers in the fluorescence spectroscopy field. Our posts on the inner filter effect and spectral measurements troubleshooting contain further advice on measurements.

When measuring fluorescence from an unknown sample it is good practice to start with a measurement of its absorbance. Fluorescence is directly proportional to absorbed light so the wavelength of maximum absorption should be determined. Some fluorescence spectroscopy instrumentation such as the Edinburgh Instruments FLS1000 or FS5 models allow absorbance as well as fluorescence measurements. It is a good idea to choose a shorter excitation wavelength than this maximum, as there might be some overlap between excitation and emission spectra.

Fluorescence Spectroscopy: absorption spectrum of anthracence

The example above shows an absorption spectrum of anthracence in cyclohexane acquired in an FS5 Spectrofluorometer. The maximum absorbance is approximately 0.1 which is a good concentration to avoid the inner filter effect. Based on this, the excitation wavelength could be set  to ~355 nm or ~375 nm.

Next, the absorption and emission wavelengths must be optimised to maximise the signal of interest. The slits of the excitation and emission monochromators can be adjusted to let more light through. This increases the signal but in turn reduces the spectral resolution (i.e, how well-resolved the spectral lines are). The signal should be high to obtain a good signal-to-noise ratio, but it should be below the detector saturation limit: too many photons per second can alter the detector behaviour and distort the data. The saturation limit for a standard PMT detector is 1.5 million cps (counts per second).

Once the conditions have been optimised, the measurement parameters can be set in the spectrometer software. Edinburgh Instruments spectrometers allow setting the wavelength range, step size, dwell time, and repeats as shown in the measurement window below. The dwell time (integration time per data point and scan) and number of scans contribute to the total integration time; obviously longer integration times will increase the quality of the data. Background subtraction and correction options are also available in the dialog.

Fluorescence Spectroscopy: Measuring fluorescence diagram depicting an Emission Scan Setup

 

The fluorescence spectroscopy software plots the data as it acquires it, resulting in a fluorescence spectrum like the one pictured below.

Diagram of fluorescence spectroscopy and measuring fluorescence

 

Fluorescence Spectroscopy Instrumentation for Measuring Fluorescence

If you have enjoyed learning about how to measure fluorescence spectrums, and would like to know more about our range of fluorescence spectrometers, please join us on social media or sign up to our infrequent newsletter via the button below and we will keep you up-to-date with all our latest scientific news and articles.

RESOURCES

Tags:
  • Frequently Asked Questions
  • FLS1000
  • FS5
  • Photoluminescence
Share:
PrevPrevious
NextNext

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}