Measurement
Method
Non-Dispersive Infrared,
Dual-Channel, Non-Interactive,
Non-Saturating |
Sensor
Rated Life
15 years
|
Sensor
Output Units
°F Dew Point or Grains/lb dry
air |
Storage
Temperature
-40°F to 170°F, (-40°C to
70°C) |
Measurement
Range
0 °F to 80 °F Dewpoint (-18°C to 26°C Dew
Point) |
Input Power
18 – 30 V AC, 50/60Hz (half
wave rectified)
1.75 VA average, 2.75 VA peak |
Typical Dew
Point Accuracy @ 77°F (25C), 27°F to 80°F DP
(-3 to 26°C DP)
(As measured against a
factory certified reference): ±1.8F (1°C)
Dew Point |
Analog Outputs (available
simultaneously):
0-10 V DC (100 Ohm output
impedance)
4 – 20 mA (RLmax – 500 Ohms) |
Typical
Grains Accuracy @ 77°F (25°C), 20 to 140
grains
(As measured against a
factory certified reference): ±2 grains/lb +
2% of reading |
Relay
Output
- Normally open and normally
closed (SPDT)
- Gold Bifurcated, 2A max @ 24 V |
Operating
Temperature Range
Room and Duct
32°F to 120°F (0°C to 50°C)
(Accessory Enclosure 1551 Required)
Outdoor
-20°F to 120°F (-29°C to 50°C) when
installed in 1551 enclosure
|
On Board
Keypad Adjustments
- Select grains/lb or °F
Dewpoint output & display
- Altitude Correction
- Measurement Range
- Analog Output range
- Zero Concentration Calibration (With
Nitrogen)
- Calibration To Ambient Air
- Relay Setpoint
- Relay Dead-Band |
Altitude Correction
User adjustable
in 500 ft increments
using keypad. |
Limited
Warranty
18 months (see warranty card
for details) |
NIST
Certified Calibration
The NIST certified
calibration of the sensor can be restored or
checked using a zero gas certified to have
less than 0.05 grains/lb dry air moisture
content. (Calibration Kit 2076) |
Installation
- Wall
- Duct with aspiration box (model 1508)
- Outside air enclosure (model 1551) |