RED-Wave NIR InGaAs Models
Range
900-1700nm or
900-2300nm
StellarNets’
high performance InGaAs
spectrometers cover the NIR wavelength range
from 0.9-1.7 μm. The
units are exceptionally robust
with no moving parts and are packaged
in small rugged metal enclosures (2.75” x 4” x
6”) for portable, process, and lab applications.
The InGaAs detector is a Sensors Unlimited
linear photo diode array with 512 pixels (1024
optional) 25μm by 500μm tall to provide
maximum sensitivity. The detector has an
integrated thermo electric cooler (TEC)
maintained at –10 °C, stabilized within +/-0.1
°C. The
RED-Wave NIR InGaAs
spectrometers use single
strand SMA 905 fiber optic input.
Several models provide a variety of operational
ranges and resolutions suitable for both
spectroscopy and optical spectrum analysis
|
Download Datasheet
 |
|
Extended Range
Extended
range systems for 1.5-2.2μm are available in 512 or 1024
element InGaAs PDA’s with 25 x
250um tall pixels. Because of reduced sensitivity and
higher dark noise, the extended
range InGaAs spectrometers are primarily used for
measuring tunable lasers, characterizing
optics, or chemical absorption & transmission
thru cuvettes, flow cells, and
dip probes.
NIR
applications include chemical ID and
moisture analysis, SpectroRadiometry and
optical power measurements, laser
characterization, microsensor
applications, and thicker
thin-film measurements
Dual
System Configurations
All NIRX-SR units can be coupled with
StellarNet’s BLACK-Comet
or UVN-SR units to cover the
entire 200-2300nm range. Coupling the units can provide
you with quick analysis of color in
the visible spectrum
and additionally compound analysis
though compound fingerprint identification in the
near infrared spectrum.
|
Specifications
Zero defect
512 detector
RED-Wave
Spectrometer |
|
Dynamic range:
4000:1 with 5
decades |
Dimensions:
150 x 100 x
68.8 mm |
|
Resolving resolution:
3.1nm with 25μm
slit |
Power consumption:
2 Amps @ 5 VDC |
|
InGaAs Detector:
512 pixel cooled
PDA array |
Interface:
USB-2 and
Parallel |
|
Detector range:
0.9-1.7μm (900-1700nm) |
Data transfer speed:
40x faster
than USB-1 |
|
Pixel
size: 25um x 500um |
Detector Integration:
1 millisecond to 30 secs |
|
Pixel well
depth: 130 x108
electrons |
Slit size options:
25, 50,100, or 200μm |
|
Selectable well control:
130 x108
or 5 x106
el. |
Operating systems:
Win98/NT/Me/00/XP/VISTA |
|
Signal to noise:
4000:1 with TEC
cooling |
Software included:
SpectraWiz
program & apps |
|
Digitizer:
14 or 16-bit |
Also free programs for:
LabView,Excel+VBA,Delphi |
|
RED-Wave
Models |
Number of Elements |
Spectrometer Range (nm) |
Grating (g/mm) |
Grating Range (nm) |
Dispersion (nm/pixel) |
Estimated Resolving Resolution |
|
NIR |
512 |
900-1700 |
250 |
800nm |
1.562 |
3.1nm |
|
NIRb |
512 |
900-1600 |
300 |
650nm |
1.269 |
2.5nm |
|
NIR2 |
512 |
1250-1575 |
600 |
325nm |
0.634 |
1.3nm |
|
NIR2b |
512 |
1150-1475 |
600 |
325nm |
0.634 |
1.3nm |
|
NIR |
1024 |
1000-1700 |
600 |
700nm |
0.683 |
1.4nm |
|
NIR3-HR |
512 |
1530-1605 |
1200 |
70nm |
0.195 |
0.4nm |
|
NIR3-HR |
1024 |
1500-1640 |
1200 |
140nm |
0.195 |
0.4nm |
|
NIRX |
512 |
1500-2200 |
300 |
700nm |
1.367 |
2.8nm |
|
NIRX |
1024 |
1500-2200 |
600 |
700nm |
0.683 |
1.4nm |
|
NIRX-SR |
512 |
900-2300 |
300 |
1400nm |
5.3 |
<13nm |
|
NIRX-SR |
1024 |
900-2300 |
600 |
1400nm |
2.7 |
<7nm |
For more information please