Technical note

 

Which Photomultiplier?

 
 

home > Analytical Instruments > Detectors

 

Detectors

Edinburgh instruments offer a range of detector modules that are suitable for either single photon counting applications or analogue detection.

Single photon counting detector modules comprise a single photon counting photomultiplier, together with an optimised dynode chain, mounted in a light tight cooled or un-cooled housing. The detector modules include the coupling flange with the adaptive optics for direct compatibility to our range of FLS920, OB920, LifeSpec and mini-tau spectrometers. Special adapters can be offered to couple to alternative systems.

Analogue detectors are used either for high light level applications with the requirement for high dynamic range or as alternative detectors in spectral ranges where photomultipliers are unavailable or too expensive. Depending on the required application, the analogue detectors come in a variety of housings with a variety of cooling options. Analogue detector modules have individual bias requirements and include different amplifiers. They come with a mounting/imaging flange attached. Analogue detectors find application in the LP920 laser flash photolysis spectrometers to extend the spectral coverage into the NIR to 2.5µm or beyond.

Edinburgh instruments have integrated many customer specific detectors into their spectrometer range. Ask the sales department or distributor for special detectors.

Single Photon Counting Detectors

Blue Sensitive Photomultiplier in Standard Housing

Spectral Range:    200-690nm
IRF:                     300 ps
Dark Count Rate:  100 cps
Blue Sensitive High Speed PMT in Standard Housing

Spectral Range:    200-650nm
IRF:                     300 ps
Dark Count Rate:  80 cps
Red Sensitive Photomultiplier in Standard Housing

Spectral Range:    200-870nm
IRF:                     300 ps
Dark Count Rate:  1000 cps
Red Sensitive High Speed PMT in Standard Housing

Spectral Range:    200-850nm
IRF:                     200 ps
Dark Count Rate:  500 cps
Red Sensitive Photomultiplier in Cooled Housing

Spectral Range:    200-870nm
IRF:                     300 ps
Dark Count Rate:  50 cps
Red Sensitive High Speed PMT in Cooled Housing

Spectral Range:    200-850nm
IRF:                     200 ps
Dark Count Rate:  50 cps
Microchannel Plate PMT in Standard Housing

Spectral Range:    200-850nm
IRF:                     50 ps
Dark Count Rate:  1000 cps
Microchannel Plate PMT in Cooled Housing

Spectral Range:    200-850nm
IRF:                     50 ps
Dark Count Rate:  10 cps
Nir PMT in Nitrogen Flow Cooled Housing

Spectral Range:    200-1400nm
IRF:                     600 ps
Dark Count Rate:  20 000 cps
Nir PMT in Nitrogen Flow Cooled Housing

Spectral Range:    200-1700nm
IRF:                     600 ps
Dark Count Rate:  200 000 cps

Analogue Detectors

   
InGaAs detector with for Steady State Applications with integrated lock-in Amplifier

InGaAs detector with for Time Resolved Applications

 

High Current Photomultiplier for Laser Flash Photolysis

 

 

 

 
 